Pasco WA-9611_13 SONOMETER User Manual

Browse online or download User Manual for Equipment Pasco WA-9611_13 SONOMETER. PASCO WA-9611_13 SONOMETER User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
012-03489E
5/95
© 1988 PASCO scientific $5.00
Instruction Manual and
Experiment Guide for
the PASCO scientific
Model WA-9611, and 9613
SONOMETER
DETECTOR
WA-9613
DRIVER
WA-9613
WA-9611
SONOMETER
KEEP WEIGHTS AS NEAR TO FLOOR
AS POSSIBLE IN THE EVENT THE
SONOMETER WIRE SHOULD BREAK
CAUTION!
1.75 kg MAXIMUM
LOAD ON LEVER
100.5 Hz
Includes
Teacher's Notes
and
Typical
Experiment Results
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - SONOMETER

012-03489E5/95© 1988 PASCO scientific $5.00Instruction Manual andExperiment Guide forthe PASCO scientificModel WA-9611, and 9613SONOMETERDETECTORWA-96

Page 2

6Sonometer 012-03489E➂ Set the function generator to produce a sine wave. Setthe frequency to a value between 100 and 200 Hz. Ad-just the amplitude to

Page 3 - Table of Contents

7012-03489E Sonometer➂ You will occasionally see higher and lower fre-quencies superimposed on the primary waveform. Itis possible for multiple standi

Page 4

8Sonometer 012-03489ETheory of Waves on a Stretched StringResonanceThe analysis above assumes that the standing wave isformed by the superposition of

Page 5 - Equipment

9012-03489E SonometerIf the analogy with Newton’s Law is accepted, and it isassumed that the wave velocity depends only on tensionand linear density,

Page 6 - Setup and Operation

10Sonometer 012-03489ENotes:

Page 7 - 012-03489E Sonometer

11012-03489E SonometerExperiment 1: Resonance Modes of a Stretched StringEQUIPMENT NEEDED:– WA-9611 Sonometer – Mass and mass hanger– WA-9613 Driver/D

Page 8 - Interface

12Sonometer 012-03489EVibratingWaveformDrivingWaveformOscilliscope ScreenFigure 1.2 String Vibrations at aMultiple of the Driving FrequencyResonant A

Page 9 - PI-4587C Function Generator

13012-03489E SonometerEQUIPMENT NEEDED:– WA-9611 Sonometer – WA-9613 Driver/Detector Coils– Function generator capable of delivering 0.5 amp – Dual tr

Page 10 - Sonometer 012-03489E

14Sonometer 012-03489EString tension(T)HangingMass(mass = M)(weight = Mg)Tension Linear Density Fundamental Wave(T) (µ) Frequency Velocity15234SlotFig

Page 11 - Spade lug

15012-03489E SonometerAnalysis➀ Use your measured string length, the fundamental frequency, and the equation V = λν to determine the velocityof the wa

Page 13 - Experiments

16Sonometer 012-03489ESuggested Research TopicsThe following are a few suggestions for further experimentation with the Sonometer.➀ Obtain two wires o

Page 14

17012-03489E SonometerTeacher’s GuideExperiment 1: Resonance Modes of a Stretched StringNoteTo avoid cross-talk between the detector and driver, keept

Page 15 - Procedure

18Sonometer 012-03489ENoteTo avoid cross-talk between the detector and driver, keepthe detector coil at least 10 cm from the driver coil duringmeasure

Page 16 - Optional

19012-03489E SonometerContacting Technical SupportBefore you call the PASCO Technical Support staff itwould be helpful to prepare the following inform

Page 18

i012-03489E SonometerTable of ContentsSection PageCopyright, Warranty and Equipment Return...iiIntr

Page 19 - Conclusions

iiSonometer 012-03489ECopyright NoticeThe PASCO scientific Model WA-9611 Sonometermanual is copyrighted and all rights reserved. However,permission i

Page 20 - Suggested Research Topics

1012-03489E SonometerIntroductionFigure 1 The Sonometer and Suggested AccessoriesDETECTORWA-9613DRIVERWA-9613WA-9611SONOMETERKEEP WEIGHTS AS NEAR TO

Page 21 - Teacher’s Guide

2Sonometer 012-03489ETo setup the sonometer (see Figure 2):➀ Choose one of the ten strings and place the brassstring retainer into the slot on the ten

Page 22 - Notes on Conclusions

3012-03489E Sonometer➤NOTE: At some lab stations, you may want thetensioning lever to hang over the left end of thetable instead of the right (see Fig

Page 23 - Technical Support

4Sonometer 012-03489E➂ Start the Power Amplifier program and set the outputto a 3-5 V sine wave; then turn on the power ampli-fier. Show channel A and

Page 24

5012-03489E Sonometer➁ Connect the BNC plug on the Sonometer DetectorCoil to the BNC adapter that is included with theDriver/Detector Coils. Connect t